АПвП-10 1×35/16 mm² — XLPE medium-voltage cable
АПвП-10 1×35/16 mm² — medium-voltage single-core power cable with an aluminium conductor, XLPE insulation, copper screen and polyethylene outer sheath. This is the АПвП construction, not АПвЭгП. Longitudinal water-blocking is not claimed for the АПвП designation without a confirmed datasheet.
| Cable designation | АПвП-10 1×35/16 |
|---|---|
| Voltage class | 10 kV |
| Construction | Single-core power cable |
| Conductor material | Aluminium |
| Nominal conductor cross-section | 35 mm² |
| Copper screen cross-section (designation) | 16 mm² |
| Insulation | Cross-linked polyethylene (XLPE) |
| Outer sheath | Polyethylene (PE) |
| Nominal frequency | 50 Hz |
| Maximum continuous conductor temperature | +90 °C |
| Conductor temperature in short circuit (reference maximum) | +250 °C |
| Operating ambient temperature (reference) | −60 … +50 °C |
| Minimum laying temperature without preheating (reference) | −20 °C |
| Minimum bending radius for single-core cable (reference) | 15× cable outer diameter |
| Laying | In ground with mechanical protection; in air with additional fire-protection measures |
| Manufacturer | To be confirmed before supply |
Important: Operating figures above are general reference limits for АПвП 10–35 kV as published in technical literature and must be verified against the actual supplying manufacturer's datasheet. Outer diameter, mass, ampacity, certification and reel length are not confirmed.
Technical reference (not a VIKAB product passport): АПвП / ПвП medium-voltage cable construction.
Technical reference – manufacturer catalogue
| Cable designation | АПвП-10 1×35/16 |
|---|---|
| Rated voltage | 10 kV |
| Aluminium conductor | 35 mm² |
| Copper screen | 16 mm² |
| Max. continuous conductor temperature | +90 °C |
| Emergency conductor temperature (reference) | +130 °C |
| Short-circuit conductor temperature (reference) | +250 °C |
The dimensional values above, where present, come from Elektrokabel Kolchuginsky manufacturer's general XLPE 10–35 kV catalogue (p. 62), and are not a product-specific ICG Supply certificate. The exact producer, manufacturing standard, certifications, measured dimensions and rated ampacity for the supplied batch must be confirmed before order. The reference images represent the general cable construction, not exact cross-sectional dimensions.
Price on request
Stock, price and lead time are confirmed upon inquiry. Please specify quantity in metres.
Request a quote on WhatsApp